Chelated lead and bone lead

Scand J Work Environ Health. 1992 Apr;18(2):113-9. doi: 10.5271/sjweh.1603.

Abstract

In this study a close correlation [correlation coefficient (r) = 0.86, P less than 0.001] was found between the blood lead level of 20 lead workers and their urinary excretion of lead for 24 h after intravenous infusion with 1 g of the chelating agent calcium disodium edetate. In addition, there were significant associations between lead levels in different bones (tibia/calcaneus: r = 0.93, P less than 0.001; tibia/phalanx: r = 0.67, P less than 0.002; calcaneus/phalanx: r = 0.80, P less than 0.001), as measured by in vivo X-ray fluorescence. Chelation produced no significant change in the lead level in either tibia or calcaneus. There was a significant correlation between chelated lead and bone lead (eg, for calcaneus, r = 0.62) in currently exposed workers. However, there was no significant relationship when a retired worker and an inactive worker were included (r = 0.14). It was concluded that chelatable lead mainly reflects the blood and soft-tissue lead pool, which is only partly dependent upon the skeletal lead content that comprises the biggest share of the total body burden.

Publication types

  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Bone and Bones / pathology*
  • Edetic Acid*
  • Humans
  • Lead / pharmacokinetics*
  • Lead Poisoning / diagnosis*
  • Lead Poisoning / urine
  • Male
  • Microscopy, Fluorescence
  • Middle Aged
  • Occupational Diseases / diagnosis*
  • Occupational Diseases / urine
  • Occupational Exposure*

Substances

  • Lead
  • Edetic Acid