Associations between type of ventilation and air flow rates in office buildings and the risk of SBS-symptoms among occupants

https://doi.org/10.1016/0160-4120(94)90141-4Get rights and content

Abstract

The association between type of ventilation and outdoor-air flow rates and Sick Building Syndrome (SBS) and SBS symptoms was studied in a cross-sectional questionnaire and field study comprising 160 office buildings, and 260–2649 respondents with case-controls as well as prevalence comparisons. Measured ventilation rates were higher than required by most building codes and consisted of fresh-air (outdoor-air) inflow of 17±14 L/p and 2.0±1.3 air changes/h. Increased risk of SBS and elevated prevalence of general SBS symptoms were associated with low outdoor-air flow rates, presence of copying machines in office rooms, and ventilation operating hours was less than 10 h/d. There was a suspected association between SBS and air humidification, recirculation of exhaust air at high outdoor-air flow rates but not at low outdoor-air flow rates, and with natural or mechanical exhaust ventilation systems. SBS was not associated with the presence of a rotary heat exchanger or with the supply air temperature higher than the room air temperature.

References (42)

  • N. Eriksson et al.

    The office illness project in northern Sweden. The significance of psychosocial factors for the prevalence of the “sick building syndrome”. A case referent study

  • W.J. Fisk et al.

    Air exchange effectiveness of conventional and task ventilation for offices

  • W.J. Fisk et al.

    The California healthy building study, Phase 1: A summary

  • S.O. Hanssen

    Increased ventilation reduces general symptoms but not sensory reactions

  • J.J.K. Jaakkola et al.

    Mechanical ventilation in office buildings and the sick building syndrome. An experimental and epidemiological study

    Indoor Air J.

    (1991)
  • J.J.K. Jaakkola et al.

    The effect of air recirculation and environmental complaints in office workers. A double-blind, four period cross-over study

  • J.J.K. Jaakkola et al.

    The Helsinki office environment study: the type of ventilation system and the “sick building syndrome”

  • Kukkonen, E.; Skåret, E.; Sundell, J.; Valbjörn, O. Indoor climate problems. Investigation and remedial measures....
  • M.J. Mendell et al.

    Consistent pattern of elevated symptoms in air-conditioned office buildings: A reanalysis of epidemiologic studies

    Public Health

    (1990)
  • R.I. Menzies et al.

    The effect of varying levels of outdoor air ventilation on symptoms of Sick building syndrome

  • N.L. Nagda et al.

    Effect of ventilation rate in a healthy building

  • Cited by (0)

    Mailing address: Lignells väg 21, S-83142 Östersund, Sweden.

    View full text