Article Text

Download PDFPDF
Predictive validity of a retrospective measure of noise exposure
  1. R McNamee1,
  2. G Burgess1,
  3. W M Dippnall1,
  4. N Cherry2
  1. 1Division of Epidemiology and Health Sciences, University of Manchester, Manchester, UK
  2. 2Department of Public Health Sciences, University of Alberta, Alberta, Canada
  1. Correspondence to:
 Dr R McNamee
 Biostatistics Group, Division of Epidemiology and Health Sciences, University of Manchester, Stopford Building, Oxford Road, Manchester M13 9PT, UK; rmcnamee{at}manchester.ac.uk

Abstract

Aims: To investigate the validity of measures of noise exposure derived retrospectively for a cohort of nuclear energy workers for the period 1950–98, by investigating their ability to predict hearing loss.

Methods: Subjects were men aged 45–65 chosen from a larger group of employees—assembled for a nested case-control study of noise and death from ischaemic heart disease—who had had at least one audiogram after at least five years’ work. Average hearing loss, across both ears and the frequencies 0.5, 1, 2, and 4 kHz, was calculated from the last audiogram for each man. Previous noise exposure at work was assessed retrospectively by three hygienists using work histories, noise survey records from 1965–98, and judgement about use of hearing protection devices. Smoking and age at the time of the audiogram were extracted from records. Differences in hearing loss between men categorised by cumulative noise exposure were assessed after controlling for age, smoking, year of test, and previous test experience.

Results: There were 186 and 150 eligible subjects at sites A and B of the company respectively who were employed for an average of 20 years. Compared to men with less than one year’s exposure to levels of 85dB(A) or greater, hearing loss was greater by 3.7 dB (90% CI −2.6 to 10.1), 3.8 dB (90% CI −2.6 to 10.3), 7.0 dB (90% CI 1.1 to 12.9) and 10.1 dB (90% CI 4.2 to 16.0) in the lowest to highest categories of cumulative noise exposure at site B. In contrast, at site A, the corresponding figures were −2.2 dB, −2.4 dB, −1.8 dB, and −4.4 dB, with no confidence interval excluding zero.

Conclusions: Noise estimation at one site was shown to have predictive validity in terms of hearing loss, but not at the other site. Reasons for the differences between sites are discussed.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Published Online First 15 June 2006

  • Funding: this study was funded by a grant from the UK Department of Health.

  • Conflict of interests: none.