Workplace protection factors for an N95 filtering facepiece respirator

J Occup Environ Hyg. 2007 Sep;4(9):698-707. doi: 10.1080/15459620701517764.

Abstract

This study evaluated the workplace performance of an N95 filtering facepiece, air-purifying respirator in a steel foundry. Air samples were collected inside and outside respirators worn by workers who were properly trained and qualitatively fit tested. For most workers, three or four pairs of air samples were collected on each of 2 days. The 49 valid sample sets were analyzed for iron, silicon, and zirconium. Only iron was present in sufficient concentrations to perform workplace protection factor (WPF) calculations. Individual WPF measurements ranged from 5 to 753. The geometric mean of the distribution was 119 with a lower 5th percentile value of 19. Time-weighted average WPFs (WPF(TWA)) were also calculated for each day for each worker as an estimate of the protection an individual might receive with daily respirator use. The WPF(TWA) values ranged from 15 for the worker with the single WPF value of 5, to a high of 684. The distribution of WPF(TWA) had a geometric mean of 120 and a lower 5th percentile of 22. Both data treatments indicate this respirator's performance was consistent with the assigned protection factor of 10 typically used for half facepiece respirators. The respirator provided adequate protection as used in this study. All contaminant concentrations inside the respirator were well below the relevant occupational exposure limits. Data collected also illustrate the dynamic nature of faceseal leakage in the workplace.

Publication types

  • Evaluation Study

MeSH terms

  • Air Pollutants, Occupational / analysis*
  • Humans
  • Inhalation Exposure / analysis*
  • Inhalation Exposure / prevention & control
  • Metallurgy*
  • Occupational Exposure / analysis*
  • Occupational Exposure / prevention & control
  • Particle Size
  • Particulate Matter / analysis
  • Respiratory Protective Devices*
  • Workplace

Substances

  • Air Pollutants, Occupational
  • Particulate Matter