Allergic and irritant reactions to rubber gloves in medical health services: Spectrum, diagnostic approach, and therapy

https://doi.org/10.1016/S0190-9622(08)80977-2Get rights and content

Delayed-type allergies account for most reactions to gloves. These have been found in 32 of 39 patients (82%) attending our department with occupationally induced contact dermatitis to gloves. Accelerators, mainly of the thiuram group, antioxidants, vulcanizers, organic pigments, and, presumably, glove powder ingredients are known responsible allergens. In contrast, immediate-type allergies to rubber gloves were less frequent (13 of 39 patients [33%] with occupationally induced glove allergies), They usually present as contact urticaria. Responsible allergens are latex, glove powder, and accelerators. On the basis of the numerous glove-related allergens, a comprehensive schedule of diagnostic tests is proposed. In addition, we introduce a new classification of hypoallergenic gloves according to their basic materials and ingredients and thus provide a guideline for individual therapy.

References (55)

  • T Estlander et al.

    Dermatitis and urticaria from rubber and plastic gloves

    Contact Dermatitis

    (1986)
  • J Hintzenstern et al.

    Frequency, spectrum and occupational relevance of type IV allergies to rubber chemicals. A retrospective study from the Department of Dermatology, University of Erlangen-Nuremberg 1/1985-3/1990

    Contact Dermatitis

    (1991)
  • A Heese et al.

    Allergien and Intoleranzreaktionen gegm Latex-Handschuhe im medizinischen Fachbereich

    Dtsch Ärztebl

    (1989)
  • PJ Frosch et al.

    Kontaktallergien auf Gummi-, Operations- and Vinylhandschuhe

    Hautarzt

    (1987)
  • L Kanerva et al.

    Organic pigment as a cause of plastic glove dermatitis

    Contact Dermatitis

    (1985)
  • AA Fischer

    Contact dermatitis

    (1986)
  • J Foussereau et al.

    Allergisches Kontaktekzem durch Isothiazolin-3-on-Derivate

    Dermatosen

    (1984)
  • W Ehl et al.

    Latex-Allergien als IgE-vermittelte Sofortreaktionen

    Allergologie

    (1988)
  • K Turjanmaa

    Incidence of immediate allergy to latex gloves in hospital personnel

    Contact Dermatitis

    (1987)
  • K Wrangsjö et al.

    Discomfort from rubber gloves indicating contact urticaria

    Contact Dermatitis

    (1986)
  • D Assalve et al.

    Contact urticaria and anaphylactoid reaction from cornstarch surgical glove powder

    Contact Dermatitis

    (1988)
  • JGK Axelsson et al.

    IgE-mediated anaphylactoid reactions to rubber

    Allergy

    (1987)
  • J Geier et al.

    Kontakturtikaria durch Gummihandschuhe

    Z Hautkr

    (1990)
  • AC Gerber et al.

    Severe intraoperative anaphylaxis to surgical gloves: latex allergy, an unfamiliar condition

    Anesthesiology

    (1989)
  • HLM van der Meeren et al.

    Life-threatening contact urticaria from glove powder

    Contact Dermatitis

    (1986)
  • C Morales et al.

    Anaphylaxis produced by rubber glove contact. Case reports and immunological identification of the antigens involved

    Clin Exp Allergy

    (1989)
  • P Zenarola

    Rubber latex allergy: unusual complication during surgery

    Contact Dermatitis

    (1989)
  • Cited by (171)

    • Surgery-Related Contact Dermatitis: A Review of Potential Irritants and Allergens

      2017, Journal of Allergy and Clinical Immunology: In Practice
      Citation Excerpt :

      Contact dermatitis due to rubber gloves, however, occurs by a different mechanism that does not involve the latex component. Instead, delayed hypersensitivity reactions are due to sensitization to rubber accelerants, including mercapto compounds, thiurams, thioureas, and carbamates, that improve elasticity of rubber products and prevent fracturing.39 Because of increased risk of NRL sensitization in health care workers relative to the general population, there is now a mandate for latex-free alternatives.

    • Clinical Patterns of Hand and Foot Dermatitis: Emphasis on Rubber and Chromate Allergens

      2009, Dermatologic Clinics
      Citation Excerpt :

      Work-up for patients with a history of urticaria from gloves should include a radioallergosorbent test to the latex protein, Hevea braziliensis (which is not entirely sensitive because of differences in the latex proteins from different sources), and testing of pieces of the glove. Prick or scratch testing should be performed only with the presence of appropriate emergency assistance because of the risk for anaphylaxis.11 Atopic dermatitis patients often react to occlusion with inflammatory response12 and may exhibit the same pattern of dermatitis as do patients with glove allergy.

    • LATEX ALLERGY

      2023, Extreme Medicine
    View all citing articles on Scopus