Table 2

Asbestos fibre concentrations at a nephrite processing factory analysed by PCM and TEM

LocationProcedureSample time (min)Air volume (L)Concentration (f/cm3)Asbestos type
PCMTEMTEM
Length ≥0.5 µmLength ≥5 µm
WorkerCutting2060.0840.4412.11.0Tremolite, actinolite
Rough grinding2060.0844.70242.9Tremolite, actinolite
Fine grinding2060.0840.180.0980.05Tremolite
Polishing16.148.368<0.059<0.062<0.062None detected
EnvironmentAmbient air76225.9630.112.10.34Tremolite
  • The samples are grouped by location and procedure.