Table 1

 Store factors and work practices by intervention group and visit

No interventionIntervention
Visit 1Visit 2p*Visit 1Visit 2p*
*Comparing visit 1 to visit 2, χ2 analysis.
Number of stores19191717
Glass breaking machine in use
    Rotary type74%74%65%0
    Glass aggregate type26%26%35%0
Raking today (% yes)74%63%0.559%0
Machine jams cleared today (% yes)26%5%0.0700
Visibly contaminated bottles in breaker, or broken manually (% yes)73%46%0.0963%7%<0.001
Full glass bins stored overnight (% yes)5%16%0.312%71%0.005
Glass bins covered (% yes)100%95%0.3100%6%<0.001
Local exhaust (% yes)0.4<0.001
    On all day32%53%0.435%6%<0.001
    On during/after breaking63%42%59%0
    Used rarely or never5%5%6%94%