Table 2

Levels of 2,4-DNT and 2,4,6-TNT found in the air in various work areas

Type of analysisMeasured value or range
Work areaStationary air samplingPersonal air sampling2,4-DNT (μg/m3)2,4,6-TNT (μg/m3)
Bending hand grenades (work rate approx. 160/h)x<0.1–1.099–690
Pressing bomblets (work rate: approx. 110/h)x0.4–2.588–560
Pressing bomblets (work rate: approx. 110/h) (sampling: 2 hours; sample volume: 60 l)x<0.5–3.222–158
Separating tabletsx0.2–2.354–305
Separating tablets (sampling: 2 hours; sample volume: 60 l)x3.7315
Opening bombletsx<0.1–1.352–118
Opening bomblets (sampling: 2 hours; sample volume: 60 l)x113250
Water treatment, removing agglomeratex<0.1–4.20.4–15
Water treatment, removing agglomeratex<0.1–201.7–46
Sucking outx4.424
Sucking out (sampling: 2 hours; sample volume: 60 l)x4.424
Selectionx<0.13.8–7.5
Selection (sampling: 2 hours; sample volume: 60 l)x<0.511
Emptying and piercingx<0.19.5–26
Emptying and piercing (sampling: 2 hours; sample volume: 60 l)x<0.52.2–25
Hand grenades (intermediate storage) (sampling: 2 hours; sample volume: 60 l)x1.0555
Rest roomx<0.5<0.1
Offices (sampling: 2 hours; sample volume: 60 l)x<0.50.17