Table 2

Glove contamination by platinum, cyclophosphamide (CP), ifosfamide (Ifos), and methotrexate (MTX)

Source of glovesnPlatinumCPIfosMTX
Gloves collected on an ad hoc basis from drug administration nursing staff, and those undertaking other ward duties where the wearing of disposable glove is usual.
Results are quoted as mean (range) in ng/glove.
Ward A used large doses of cyclophosphamide, ifosfamide, and methotrexate. Ward B used large doses of platinum containing drugs. ND, non-detected.
Ward A: drug administration team55.05 (3.4–6.8)NDNDND
Ward A: other ward duties41.4 (0.4–2.4)NDNDND
Ward B: drug administration team319.5 (5.8–36)ND673 (ND–1806)34.7 (ND–49.3)
Ward B: other ward duties43.1 (2.4–4)2.8 (ND–11.2)5.2 (ND–20.9)11.8 (ND–27)
Blank disposable latex glove2<1NDND<20
Detection limits (ng/glove)0.245518