Type of potroom and job | Period | PAH (μg/m3) | Measurements (n) |
Open prebaked: | |||
All workers | 1919–41 | — | — |
HS Søderberg: | |||
Potroom worker | 1939–60 | 150 | — |
1961–78 | 100 | 31-150 | |
Supervisor | 1939–60 | 120 | — |
1961–78 | 80 | 31-150 | |
Stud puller | 1939–60 | 300 | — |
1961–78 | 200 | 31-150 | |
Day maintenance | 1939–60 | 300 | — |
1961–78 | 200 | 3 1-150 | |
VS Søderberg: | |||
Potroom worker | 1958–69 | 200 | — |
1970–79 | 150 | 141-151 | |
1980–85 | 75 | 601-151 | |
1986–95 | 25 | 170 | |
Stud puller | 1958–69 | 1500 | — |
1970–79 | 1200 | 141-151 | |
1980–84 | 900 | 601-151 | |
1985–95 | 100 | 50 | |
Day maintenance | 1958–69 | 300 | — |
1970–79 | 200 | 141-151 | |
1980–85 | 120 | 601-151 | |
1986–95 | 40 | 108 | |
Hooded prebaked: | |||
All workers | 1981–95 | <2 | 31 |
Anode production | 1918–19 | 50 | — |
1920–38 | 125 | — | |
1939–78 | 100 | 1 1-152 | |
Anode mounting | 1981–95 | 5 | 38 |
Potlining | 1981–95 | 75 | 178 |
↵1-150 The same three stationary measurements in the potrooms.
↵1-151 The same 14 and 60 stationary measurements in the potroom.
↵1-152 One stationary measurement.
Bold=estimates based directly on personal measurements; normal=estimates based on relative changes in stationary measurements; italics=estimates based on assignment from a panel of three people familiar with the industry.