rss
Occup Environ Med 2009;66:325-334 doi:10.1136/oem.2008.039032
  • Original article

A panel study of air pollution in subjects with heart failure: negative results in treated patients

  1. J L Barclay1,
  2. B G Miller2,
  3. S Dick3,
  4. M Dennekamp3,4,
  5. I Ford5,
  6. G S Hillis1,
  7. J G Ayres3,
  8. A Seaton3
  1. 1
    Department of Cardiology, Aberdeen Royal Infirmary, Aberdeen, UK
  2. 2
    Institute of Occupational Medicine, Edinburgh, UK
  3. 3
    Department of Environmental and Occupational Medicine, University of Aberdeen, Aberdeen, UK
  4. 4
    Department of Epidemiology and Preventive Medicine, Monash University, Melbourne, Australia
  5. 5
    Department of Medicine and Therapeutics, University of Aberdeen, UK
  1. Justin Barclay, Department of Cardiology, Aberdeen Royal Infirmary, Foresterhill, Aberdeen AB25 2ZP, UK; j.barclay{at}abdn.ac.uk
  • Accepted 25 September 2008
  • Published Online First 18 November 2008

Abstract

Objectives: To investigate preclinical adverse effects of ambient particulate air pollution and nitrogen oxides in patients with heart failure.

Methods: A cohort of 132 non-smoking patients living in Aberdeen, Scotland, with stable chronic heart failure were enrolled in a repeated-measures panel study. Patients with atrial fibrillation or pacemakers were excluded. Participants were studied for 3 days every 2 months for up to 1 year with monitoring of pollutant exposure and concurrent measurements of pathophysiological responses. Measurements included daily area concentration of particulate matter with a median aerodynamic diameter of <10 micrometres (PM10), particle number concentration (PNC) and nitrogen oxides; daily estimated personal concentration of particulate matter with a median aerodynamic diameter of <2.5 micrometres (PM2.5) and PNC exposures; and 3-day cumulative personal nitrogen dioxide (NO2). Concurrent meteorological data were recorded. Blood was taken at the end of each 3-day block for assays of markers of endothelial activation, inflammation and coagulation. Cardiac rhythm was monitored by ambulatory Holter monitor during the final 24 h of each block.

Results: The average 24 h background ambient PM10 ranged from 7.4 to 68 μg.m−3 and PNC from 454 to 11 283 particles.cm−3. No associations were demonstrated between the incidence of arrhythmias, heart rate variability or haematological/biochemical measures and any variations in pollutant exposures at any lags.

Conclusion: Assuming that low-level pollution affects the parameters measured, these findings may suggest a beneficial effect of modern cardioprotective therapy, which may modify responses to external risk factors. Widespread use of such drugs in susceptible populations may in future reduce the adverse effects of air pollution on the heart.

Footnotes

  • Competing interests: None.

  • Funding: This study was supported by a grant (0020010) from the UK Department of Health Policy Research Programme.

  • Ethics approval: The study protocol was approved by the local ethics committee.

  • Patient consent: Obtained.

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of OEM.
View free sample issue >>

Free archive
The full back archive is now available for OEM. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.