Occup Environ Med 61:135-142 doi:10.1136/oem.2002.000489
  • Original article

Accuracy of task recall for epidemiological exposure assessment to construction noise

Table 7

Comparison of noise estimates

Trade No. of subjects Mean estimated exposure, LEQ dBA (SD) Bias 95% CI of the bias (%) accuracy
*Significantly different from zero at the 0.05 level, 95% confidence intervals do not include zero.
†Other trades included labourer, sheet metal worker, sprinkler fitter, and operating engineer.
Dosimetry Activity card
All subjects 17 87.2 (3.9) 88.7 (3.5) −1.5* −2.7 to −0.3 97
Carpenter 8 89.9 (2.0) 91.9 (1.4) −2.0* −3.5 to −0.4 97
Electrician 5 84.0 (2.6) 85.0 (0.5) −1.0 −4.0 to 2.0 97
Other† 4 85.6 (4.9) 86.9 (2.3) −1.3 −6.9 to 4.3 96
Dosimetry Questionnaire
All subjects 23 86.3 (4.5) 87.9 (4.3) −1.7* −2.9 to −0.4 97
Carpenter 10 89.9 (1.8) 91.9 (2.0) −2.0* −3.8 to −0.3 97
Electrician 8 83.1 (3.4) 85.1 (0.8) −2.0 −4.9 to 1.0 96
Other† 5 84.2 (5.3) 84.6 (4.6) −0.4 −4.4 to 3.5 96
Activity card Questionnaire
All subjects 16 88.9 (3.5) 88.8 (3.6) 0.1 −0.6 to 0.5 99
Carpenter 8 91.9 (1.5) 91.7 (2.3) 0.2 −0.9 to 1.3 99
Electrician 4 84.9 (0.5) 85.4 (0.6) −0.5 −1.7 to 0.8 99
Other† 4 86.9 (2.3) 86.5 (2.4) 0.4* 0.1 to 0.8 99