rss
Occup Environ Med 59:608-612 doi:10.1136/oem.59.9.608
  • Original article

Occupational exposure to cytotoxic drugs in two UK oncology wards

Table 2

Glove contamination by platinum, cyclophosphamide (CP), ifosfamide (Ifos), and methotrexate (MTX)

Source of gloves n Platinum CP Ifos MTX
Gloves collected on an ad hoc basis from drug administration nursing staff, and those undertaking other ward duties where the wearing of disposable glove is usual.
Results are quoted as mean (range) in ng/glove.
Ward A used large doses of cyclophosphamide, ifosfamide, and methotrexate. Ward B used large doses of platinum containing drugs. ND, non-detected.
Ward A: drug administration team 5 5.05 (3.4–6.8) ND ND ND
Ward A: other ward duties 4 1.4 (0.4–2.4) ND ND ND
Ward B: drug administration team 3 19.5 (5.8–36) ND 673 (ND–1806) 34.7 (ND–49.3)
Ward B: other ward duties 4 3.1 (2.4–4) 2.8 (ND–11.2) 5.2 (ND–20.9) 11.8 (ND–27)
Blank disposable latex glove 2 <1 ND ND <20
Detection limits (ng/glove) 0.24 5 5 18

This Article

Free sample

This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of OEM.
View free sample issue >>