1 Year change of heart rate variability and frequency of premature complexes between baseline and the 1 year measurement

Day workers Shift workers p Value of difference between day and shift worker
n 22 49
Mean number of night shifts worked between the baseline and repeated measurement 0 63
Frequency of premature complexes (%):
 Decrease of PAC 54.6 43.7 0.62-151
 No change in PAC 4.6 0.0
 Increase in PAC 40.9 56.3
 Decrease of PVC 45.4 20.4 0.032-151
 No change in PVC 27.3 30.6
 Increase in PVC 27.3 48.9
Heart rate variability:
 Heart rate (bpm) 1.83 −2.082-150 0.08
 SDNNi (ms) −7.02-150 −2.0 0.2
 Loglow (10−3 log ms) −36.9 −29.9 0.84
 Loghigh (10−3 log ms) −83.92-150 −16.2 0.06
 % lf 1.99 −0.72 0.16
  • PAC=premature atrial complexes; PVC=premature ventricular complexes; SDNNi=mean of all 5 minute standard deviations of NN intervals; Loglow=power in the low frequency range (0.05–015 Hz) in logarithmic units; Loghigh=power in the high frequency range (0.15–0.40 Hz.) in logarithmic units; % lf=low frequency power (0.05–0.15 Hz) in normalised units.

  • 2-150 p<0.05 v baseline.

  • 2-151 p Value according to Wilcoxon two sample test.