rss
Occup Environ Med 1997;54:73-89 doi:10.1136/oem.54.2.73
  • Research Article

Measurement, evaluation, and assessment of occupational exposures to hand-transmitted vibration.

  1. M J Griffin
  1. Human Factors Research Unit, University of Southampton.

      Abstract

      The measurement of hand-transmitted vibration converts oscillatory movements to a form in which they can be evaluated with respect to human responses and assessed for their acceptability. This paper presents methods of measurement, evaluation, and assessment currently advocated in standards and other forms of guidance. The degree to which the methods of evaluating different frequencies, directions, and durations of vibration affect the assessment of vibration on different tools is illustrated. With the frequency weighting currently used to allow for the effects of different frequencies there is little need to measure vibration at frequencies as high as 1000 Hz; this has significant implications to the design and evaluation of proposed antivibration devices, including gloves. Without the current frequency weighting, vibration at frequencies greater than 250 Hz can contribute to the magnitude of the vibration, but many common causes of injury from hand-transmitted vibration have their dominant components of vibration below 250 Hz. On many powered tools, although the dominant frequency of vibration is the same before and after frequency weighting, the reported magnitude of vibration is greatly affected by the frequency weighting. On tools with dominant low frequencies, their vibration is rated as being of far greater importance relative to other tools when considering frequency-weighted acceleration than when considering unweighted acceleration. It is shown that the effect of considering three axes of vibration as opposed to one axis has a greater effect on some tools than on others. The uncertainties and assumptions involved in the measurement, evaluation, and assessment of hand-transmitted vibration are reviewed. It is suggested that whereas current decisions on health and welfare should be based on current assessment methods, the measurement and evaluation of hand-transmitted vibration should involve the collection and reporting of data which allow other interpretations in the future.

      This Article

      Services

      1. Request permissions

      Responses

      1. Submit a response
      2. No responses published

      Social bookmarking

      Register for free content


      Free sample
      This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of OEM.
      View free sample issue >>

      Free archive
      The full back archive is now available for OEM. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
      Register to access the free archive >>

      Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.