Occupational asthma due to an emulsified oil mist.

Abstract

A toolsetter developed occupational asthma due to the oil mist generated by his lathe on which it was used as a coolant. The diagnosis was confirmed by serial measurements of peak expiratory flow at home and work, including a prolonged period away from work. Occupational type bronchial provocation tests were performed using the whole emulsified oil and its components separately. He reacted specifically to the whole emulsified oil and to the reodorant, a pine oil preparation. He also reacted to colophony, a constituent of the emulsifier.

This Article

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of OEM.
View free sample issue >>

Free archive
The full back archive is now available for OEM. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.