Br J Ind Med 1967;24:52-59 doi:10.1136/oem.24.1.52
  • Articles

Heat-protective Ventilated Jackets: A Comparison of Humid and Dry Ventilating Air

  1. G. W. Crockford,
  2. D. E. Lee
  1. M.R.C. Environmental Physiology Research Unit, London School of Hygiene and Tropical Medicine, London

      Abstract

      A comparison has been made between humid and dry air for ventilating a heat-protective jacket. At sensible cooling capacities of 4·5 kcal./min. and above, humid and dry air provided equal protection. At sensible cooling capacities of 4 kcal./min. and above, the subject achieved thermal equilibrium within 65 min. with both humid and dry air, but below this value humid ventilating air is associated with elevated sweat rates and a failure to achieve thermal equilibrium within 65 minutes.

      Register for free content


      Free sample
      This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of OEM.
      View free sample issue >>

      Free archive
      The full back archive is now available for OEM. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.