Occup Environ Med. Published Online First: 3 May 2007. doi:10.1136/oem.2006.031146
Original Article |
Limits of longitudinal decline for the interpretation of annual changes in FEV1 in individuals
1 National Institute for Occupational Safety and Health, United States
2 Constella Group, United States
3 University of California Los Angeles, United States
4 Phoenix Fire Department, United States
5 Tulane Medical School, United States
* To whom correspondence should be addressed. E-mail: exh6{at}cdc.gov.
Accepted 20 April 2007
Abstract
Objective:
Spirometry based screening programs often conduct annual assessment of longitudinal changes in FEV1 in order to identify individuals with excessive decline. Both the American Thoracic Society (ATS) and the American College of Occupational and Environmental Medicine (ACOEM) recommend a reference limit value of ¡
15% for excessive annual decline. Neither ATS nor ACOEM adjust this limit for the precision of the existing spirometry data. We propose an improved method of defining the reference limit of longitudinal annual FEV1 decline (LLD) based on the precision of the spirometry data.
Method:
We used data from four monitoring programs and measured their data precision using a pair-wise within-person variation statistic. We then derived program- and gender-specific absolute and relative LLD values and validated these against the 95th percentiles for observed yearly changes in FEV1.
Results: The relative limit method was more practical than the absolute limit as it adjusted for gender differences in the magnitude of FEV1. The program-specific relative limit values were in good agreement with 95th percentiles for year-to-year FEV1 changes and ranged from 6.6% to 15.8%. For individuals with COPD and bronchial hyperreactivity the 95th percentiles for year-to-year changes were about 15% and higher.
Conclusions:
The relative longitudinal limit for annual FEV1 decline based upon precision of measurements is valid and generalizable for different gender and population groups. A relative limit of approximately 10% appears appropriate for good quality workplace monitoring programs, whereas a limit of about 15% appears appropriate for clinical evaluation of individuals with an obstructive airway disease. Computer software based on the method described is available from the corresponding author.
Keywords: longitudinal spirometry, lung function, screening, workplace monitoring
This article has been cited by other articles:
-
Harber, P., Levine, J., Bansal, S.
(2009). How Frequently Should Workplace Spirometry Screening Be Performed?: Optimization Via Analytic Models. Chest
136: 1086-1094
[Abstract] [Full Text] -
Loomis, D.
(2007). Work in brief. Occup. Environ. Med.
64: 639-639
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.