Register for email alerts and news feeds:
This journal | BMJ Group
rss
Occupational and Environmental Medicine 2005;62:695-701; doi:10.1136/oem.2004.018424
Copyright © 2005 by the BMJ Publishing Group Ltd.

ORIGINAL ARTICLE

The precision of longitudinal lung function measurements: monitoring and interpretation

E Hnizdo1, L Yu2, L Freyder3, M Attfield1, J Lefante4, H W Glindmeyer3

1 Division of Respiratory Disease Studies, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA
2 Constella Health Sciences, Morgantown, WV, USA
3 Section of Pulmonary, Critical Care, and Environmental Medicine, Department of Medicine, Tulane Medical School, New Orleans, LA, USA
4 Department of Biostatistics, Tulane School of Public Health and Tropical Medicine, New Orleans, LA, USA

Correspondence to:
Correspondence to:
Dr E Hnizdo
Division of Respiratory Disease Studies, National Institute for Occupational Safety and Health, 1095 Willowdale Road, Morgantown, WV 26505; ehnizdo{at}cdc.gov

Background: The efficacy of decision making based on longitudinal spirometric measurements depends critically on the precision of the available data, which is determined by the magnitude of the within-person variation.

Aims: Firstly, to describe and investigate two statistical methods—a pairwise estimate of within-person standard deviation sp and the reliability coefficient G—for use in the monitoring of precision of longitudinal measurements of forced expiratory volume in one second (FEV1). Secondly, to investigate the effect of longitudinal data precision on the detectable excess rate of decline in FEV1.

Methods: The authors "monitored" retrospectively on a yearly basis the magnitude of the within-person variation sp and the coefficient G in 11 workplace based spirometric monitoring programmes conducted from 1987 to 2001 on 12 729 workers in various industrial plants.

Results: The plant-specific mean values p (range 122–166 ml) and (range 0.88–0.95), averaged over all years of follow up, correlated well with the plant-specific within-person standard deviation sr (range 130–177 ml) estimated from all longitudinal data. The correlations were 0.90 for p and 0.68 for . The average precision of the longitudinal FEV1 measurements affected the duration of follow up needed to identify a "true" excess rate of decline in FEV1 in an individual.

Conclusions: The results show that monitoring of longitudinal spirometry data precision (1) allows that data precision can be improved or maintained at levels that allow individuals with a rapid decline to be identified at an earlier age; and (2) attaches a measure of precision to the data on which decision making is based.

Abbreviations: ATS, American Thoracic Society; COPD, chronic obstructive pulmonary disease; FEV1, forced expiratory volume in one second; FVC, forced vital capacity; LLNR, lower limit of normal for the regression line

Keywords: spirometry screening; longitudinal spirometry; spirometry monitoring; the coefficient of reliability


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Hnizdo, E., Sircar, K., Yan, T., Harber, P., Fleming, J., Glindmeyer, H. W (2007). Limits of longitudinal decline for the interpretation of annual changes in FEV1 in individuals. Occup. Environ. Med. 64: 701-707 [Abstract] [Full Text]  
  • Fishwick, D., Naylor, S. (2007). COPD and the workplace. Is it really possible to detect early cases?. Occup Med (Lond) 57: 82-84 [Full Text]  
  • Wang, M. L., Avashia, B. H., Petsonk, E. L. (2006). Interpreting Periodic Lung Function Tests in Individuals: The Relationship Between 1- to 5-Year and Long-term FEV1 Changes.. Chest 130: 493-499 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Occupational, Public, Community health jobs

Occupational, Public, Community health jobs