Register for email alerts and news feeds:
This journal | BMJ Group
rss
Occupational and Environmental Medicine 2004;61:628-635; doi:10.1136/oem.2003.009753
Copyright © 2004 by the BMJ Publishing Group Ltd.
Occupational and Environmental Medicine 2004;61:628-635
© 2004 BMJ Publishing Group Ltd

ORIGINAL ARTICLE

Point-of-sale glass bottle recycling: indoor airborne exposures and symptoms among employees

S M Kennedy, R Copes, K H Bartlett, M Brauer

School of Occupational and Environmental Hygiene, University of British Columbia, Vancouver BC, Canada

Correspondence to:
Correspondence to:
Prof. S M Kennedy
School of Occupational and Environmental Hygiene, University of British Columbia, 2206 East Mall, Vancouver BC, V6T 1Z3, Canada; kennedy{at}interchange.ubc.ca

Aims: To assess the impact of newly introduced point-of-sale glass bottle recycling on indoor air quality and employee health.

Methods: Airborne exposures and both chronic and acute respiratory and somatic symptoms were surveyed among 226 employees at 36 randomly selected liquor stores with bottle recycling and in-house glass breaking. Each store was visited twice; between visits glass breaking was discontinued for one month in half the stores (selected at random), although bottles were still collected and stored on site. Rates of chronic symptoms were compared to an external, unexposed control population.

Results: Geometric mean exposure levels were 0.18 mg/m3 for inhalable particulate matter and 3.6 EU/m3 for endotoxin (270 personal samples); 1064 CFU/m3 for viable fungi (648 area samples). Fungal levels were associated with visibly mouldy bottles being broken, outdoor fungal counts, and uncovered glass bins. Exposures were not altered by the intervention of shutting down glass breaking machinery. Compared to controls, employees reported more work related chronic chest tightness and chronic nasal symptoms. Acute chest symptoms were associated with breaking visibly mouldy bottles, but not with measured fungal counts. Inhalable particulate matter levels >0.2 mg/m3 were associated with acute upper airway irritation. Somatic symptoms were associated with measures of psychosocial job strain.

Conclusion: Results suggest that this type of recycling programme may generate fungal exposures sufficient to elicit upper airway and chest symptoms.

Keywords: bioaerosols; indoor air quality; fungal exposures; recycling


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Occupational, Public, Community health jobs

Occupational, Public, Community health jobs