© 2003 BMJ Publishing Group
ORIGINAL ARTICLE
Agreement between hearing thresholds measured in non-soundproof work environments and a soundproof booth
Department of Community and Family Medicine, The Chinese University of Hong Kong
Correspondence to:
Correspondence to:
Professor Tze Wai Wong, Department of Community and Family Medicine, The Chinese University of Hong Kong, 4/F, School of Public Health, Prince of Wales Hospital, Shatin, NT, Hong Kong;
twwong{at}cuhk.edu.hk
Aims: To study the agreement between audiometric test results measured in non-soundproof environments at the worksite, and in a soundproof booth.
Methods: In a cross sectional prevalence study on noise induced hearing loss, 885 transport workers whose hearing thresholds were measured by a standard audiometric test method in non-soundproof environments at the worksite were identified to have some hearing loss (>25 dB), and were retested in a soundproof booth.
Results: At 48 KHz, the mean of the absolute differences in hearing threshold obtained by these two methods was 2 dB or less. When the proportions of hearing loss (
30 dB for any frequencies at 38 KHz, or
90 dB for three low frequencies at 0.52 KHz, or
90 dB for three high frequencies at 36 KHz) were compared, considerable differences existed. A much better agreement was obtained when the criteria for hearing loss as measured in the field test under non-soundproof conditions were relaxed by 5 dB. At 4 KHz, the difference between the proportion of subjects with hearing loss as measured in the field and that as measured in the booth was the smallest. The kappa statistic was highest at 3 and 4 KHz.
Conclusions: Audiometric test results conducted in non-soundproof environments in the field are comparable to those obtained in a soundproof environment among transport workers with a hearing loss of >25 dB. The hearing threshold at 4 KHz appears suitable for the estimation of the prevalence of hearing loss when appropriate adjustments are made in the diagnostic criteria.
Keywords: agreement; noise; hearing loss; hearing threshold
Abbreviations: ANSI, American National Standards Institute; NIHL, noise induced hearing loss
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
