Occupational and Environmental Medicine, Vol 56, 758-764
PAPERS |
Development of an expert system for the interpretation of serial peak expiratory flow measurements in the diagnosis of occupational asthma. Midlands Thoracic Society Research Group
PS Burge, CF Pantin, DT Newton, PF Gannon, P Bright, J Belcher, J McCoach, DR Baldwin and CB Burge
Occupational Lung Disease Unit, Birmingham Heartlands Hospital, UK.
If asthma is due to work exposures there must be a relation between these exposures and the asthma. Asthma causes airway hyperresponsiveness and obstruction; the obstruction can be measured with portable meters, which usually measure peak expiratory flow, or sometimes forced expiratory volume in 1 second (FEV1). These can be measured serially (for instance 2 hourly) over several weeks at and away from work. Once occupational asthma develops, the asthma will be induced by many non-specific triggers common to non-occupational asthma. The challenge is to identify changes in peak expiratory flow due to work among other non-occupational causes. Standard statistical tests have been found to be insensitive or non-specific, principally because of the variable period for deterioration to occur after exposure, and the sometimes prolonged time for recovery to occur, such that days away from work may initially have lower measurements than days at work. A computer assisted diagnostic aid (Oasys) has been developed to separate occupational from non-occupational causes of airflow obstruction. Oasys-2 is based on a discriminant analysis, and achieved a sensitivity of 75% and a specificity of at least 94%; therefore peak expiratory flow monitoring combined with Oasys-2 analysis is better to confirm than to exclude occupational asthma. A neural network version in development has improved on this. Both have been based on expert interpretation of peak flow measurements plotted as daily maximum, mean, and minimum, with the first reading at work taken as the first reading of the day. Oasys has been evaluated with independent criteria against measurements made in a wide range of occupational situations. Oasys is sufficiently developed to be the initial method for the confirmation, although less so for exclusion of occupational asthma.
Copyright © 1999 Occupational and Environmental Medicine
This article has been cited by other articles:
-
Moore, V. C., Jaakkola, M. S., Burge, C. B. S. G., Pantin, C. F., Robertson, A. S., Vellore, A. D., Burge, P. S.
(2009). PEF analysis requiring shorter records for occupational asthma diagnosis. Occup Med (Lond)
59: 413-417
[Abstract] [Full Text] -
Moore, V. C., Cullinan, P., Sadhra, S., Burge, P. S.
(2009). Peak expiratory flow analysis in workers exposed to detergent enzymes. Occup Med (Lond)
59: 418-423
[Abstract] [Full Text] -
Moore, V. C., Jaakkola, M. S., Burge, C. B. S. G., Robertson, A. S., Pantin, C. F. A., Vellore, A. D., Burge, P. S.
(2009). A New Diagnostic Score for Occupational Asthma: The Area Between the Curves (ABC Score) of Peak Expiratory Flow on Days at and Away From Work. Chest
135: 307-314
[Abstract] [Full Text] -
Tarlo, S. M., Balmes, J., Balkissoon, R., Beach, J., Beckett, W., Bernstein, D., Blanc, P. D., Brooks, S. M., Cowl, C. T., Daroowalla, F., Harber, P., Lemiere, C., Liss, G. M., Pacheco, K. A., Redlich, C. A., Rowe, B., Heitzer, J.
(2008). Diagnosis and Management of Work-Related Asthma: American College of Chest Physicians Consensus Statement. Chest
134: 1S-41S
[Abstract] [Full Text] -
Bakerly, N. D., Moore, V. C., Vellore, A. D., Jaakkola, M. S., Robertson, A. S., Burge, P. S.
(2008). Fifteen-year trends in occupational asthma: data from the Shield surveillance scheme. Occup Med (Lond)
58: 169-174
[Abstract] [Full Text] -
Bolen, A. R, Henneberger, P. K, Liang, X., Sama, S. R, Preusse, P. A, Rosiello, R. A, Milton, D. K
(2007). The validation of work-related self-reported asthma exacerbation. Occup. Environ. Med.
64: 343-348
[Abstract] [Full Text] -
Hegewald, M. J., Lefor, M. J., Jensen, R. L., Crapo, R. O., Kritchevsky, S. B., Haggerty, C. L., Bauer, D. C., Satterfield, S., Harris, T., for the Health, Aging, and Body Composition Study,
(2007). Peak Expiratory Flow Is Not a Quality Indicator for Spirometry: Peak Expiratory Flow Variability and FEV1 Are Poorly Correlated in an Elderly Population. Chest
131: 1494-1499
[Abstract] [Full Text] -
Sanders, D. L., Aronsky, D.
(2006). Biomedical Informatics Applications for Asthma Care: A Systematic Review. J. Am. Med. Inform. Assoc.
13: 418-427
[Abstract] [Full Text] -
Anees, W., Gannon, P.F., Huggins, V., Pantin, C.F.A., Burge, P.S.
(2004). Effect of peak expiratory flow data quantity on diagnostic sensitivity and specificity in occupational asthma. Eur Respir J
23: 730-734
[Abstract] [Full Text] -
Gautrin, D., Newman-Taylor, A.J., Nordman, H., Malo, J-L.
(2003). Controversies in epidemiology of occupational asthma. Eur Respir J
22: 551-559
[Abstract] [Full Text] -
Beach, J., Hoffman, H.
(2003). An Oasys for occupational asthma. CMAJ
169: 189-189
[Full Text] -
Anees, W, Huggins, V, Pavord, I D, Robertson, A S, Burge, P S
(2002). Occupational asthma due to low molecular weight agents: eosinophilic and non-eosinophilic variants. Thorax
57: 231-236
[Abstract] [Full Text] -
ANEES, W, ROBERTSON, A S, BURGE, P S, VYAS, A, NIVEN, R M., PICKERING, C A C
(2001). Glutaraldehyde induced asthma in endoscopy nursing staff.. Occup. Environ. Med.
58: 544-544
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.