Ventilation rate in office buildings and sick building syndrome.

J J Jaakkola, P Miettinen

Department of Public Health, University of Helsinki, Finland.

OBJECTIVE--To examine the relation between ventilation rate and occurrence of symptoms of the eyes, nose, throat, and skin as well as general symptoms such as lethargy and headache, often termed the sick building syndrome. METHODS--A cross sectional population based study was carried out in 399 workers from 14 mechanically ventilated office buildings without air recirculation or humidification, selected randomly from the Helsinki metropolitan area. The ventilation type and other characteristics of these buildings were recorded on a site visit and the ventilation in the rooms was assessed by measuring the airflow through the exhaust air outlets in the room. A questionnaire directed at workers inquired about the symptoms and perceived air quality and their possible personal and environmental determinants (response rate 81%). The outcomes were weekly work related symptoms experienced during the previous 12 months and symptom groups defined either by their anatomical location or hypothesised mechanism. RESULTS--In logistic regression analysis, the adjusted odds ratio (OR) for any symptom of interest was 3.03 (95% confidence interval (95% CI) 1.13 to 8.10) in the very low ventilation category of below 5 l/s per person and 2.24 (0.89 to 5.65) in the high ventilation category of over 25 l/s per person compared with the reference (15- < 25 l/s). The ORs for ocular (1.27, 1.11 to 1.46), nasal (1.17, 1.06 to 1.29), skin symptoms (1.18, 1.05 to 1.32), and lethargy (1.09, 1.00 to 1.19) increased significantly by a unit decrease in ventilation from 25 to 0 l/s per person. CONCLUSION--The results suggest that outdoor air ventilation rates below the optimal (15 to 25 l/s per person) increase the risk of the symptoms of sick building syndrome with the sources of pollutants present in mechanically ventilated office buildings. The Finnish guideline value is 10 l/s per person.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Mendell, M J, Fisk, W J, Stafford, M, Marmot, M, J Eley, M., Stansfield, S (2007). Is health in office buildings related only to psychosocial factors? * Authors' reply. Occup. Environ. Med. 64: 69-70 [Full Text]  
  • Gevecker Graves, C., Tardiff, R. G., Jaakkola, M. S., Jaakkola, J. J. K. (2000). RE: "OFFICE EQUIPMENT AND SUPPLIES: A MODERN OCCUPATIONAL HEALTH CONCERN?". Am J Epidemiol 152: 593-594 [Full Text]  
  • Niven, R M., Fletcher, A M, Pickering, C A C, Faragher, E B, Potter, I N, Booth, W B, Jones, T J, Potter, P D R (2000). Building sickness syndrome in healthy and unhealthy buildings: an epidemiological and environmental assessment with cluster analysis. Occup. Environ. Med. 57: 627-634 [Abstract] [Full Text]  
  • Menzies, D., Bourbeau, J. (1997). Building-Related Illnesses. NEJM 337: 1524-1531 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.

Occupational, Public, Community health jobs

Occupational, Public, Community health jobs